BMCMG - POLY-GLASS NO. 16 CATALYST TOPCOAT CONVERTE

  • MSDS: BMCMG
  • Manufacturer: NORTH AMERICAN POLYMER CO INC
  • Product Name: POLY-GLASS NO. 16 CATALYST TOPCOAT CONVERTE
  • National Stock Number: 8040-00N025433
Product Identification

Product ID:POLY-GLASS NO. 16 CATALYST TOPCOAT CONVERTE
MSDS Date:12/01/1989
FSC:8040
NIIN:00N025433
MSDS Number: BMCMG

Responsible Party
NORTH AMERICAN POLYMER CO INC
1914 N MILWAUKEE AVE
CHICAGO, IL 60647
US

Emergency Phone: 312-622-7153

Info Phone: 312-486-8881

Cage: N0RAM

Contractor
NORTH AMERICAN POLYMER CO INC
6800 CHICAGO, IL 60647 US

Telephone: 312-622-7153

Cage: N0RAM

Ingredients

10.

CAS: 1330-20-7

RTECS: ZE2100000

Fraction By Weight: 3%

OSHA PEL 100 PPM;150 PPM STEL

ACGIH TLV: 100 PPM;150 PPM STEL

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


TOLUENE (SARA III)

CAS: 108-88-3

RTECS: XS5250000

Fraction By Weight: 10 - 30%

OSHA PEL 200 PPM/150 STEL

ACGIH TLV: 50 PPM; 9293

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


86.

CAS: 141-78-6

RTECS: AH5425000

Fraction By Weight: 21%

OSHA PEL 400 PPM

ACGIH TLV: 400 PPM

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


ETHANOL, 2-ETHOXY-, ACETATE; (CELLOSOLVE ACETATE) (EGEEA).

CAS: 111-15-9

RTECS: KK8225000

Fraction By Weight: 25%

OSHA PEL 100 PPM, S

ACGIH TLV: 5 PPM, S


HEXANE, 1,6-DIISOCYANATO-; (1,6-HEXAMETHYLENE DIISOCYANATE)

CAS: 822-06-0

RTECS: MO1740000

Fraction By Weight: 41%

OSHA PEL 0.02 PPM (MFR)

ACGIH TLV: 0.005 PPM

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


SUBSEQUENT EXPOS EVEN BELOW TLV. ONCE SENSITIZED,

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:EYES:CAN CAUSE SEVERE IRRIT,
REDNESS, TEARING & BLURRED VISION. SKIN:PRLNG/RPTD CONTACT CAN
CAUSE MOD IRRIT, DEFAT & DERM. HARMFUL/FATAL IF ABSORBED.
INHAL:EXCESS INHAL OF VAPORS CAN CAUSE NASAL , RESP IRRIT, DIZZ,
WEAK, FATG, HDCH, POSSIBLE UNCON & EVEN ASPHY. INGEST:HARMFUL/FATAL
& CAN CAUSE (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:BURNING SENSA, NAUS, VOMIT, DIARR.
CHRONIC:REPORTS HAVE ASSOC RPTD/PRLNG OCCUP OVEREXP TO SOLVS W/PERM
BRAIN & NERV SYS DMG. MISUSE BY DELIB CONC & INHAL CONTENTS MAY BE
HARMFUL/FATAL. OVEREX P MAY CAUSE BLOOD DISORDERS. BASED ON TESTS
W/LAB ANIMALS, OVEREXP MAY CAUSE REPRO DISORDERS & BIRTH DEFECTS.
(SUPDAT)
Medical Cond Aggravated by Exposure:ONCE A PERSON IS DIAGNOSED AS
SENSITIZED TO AN ISOCYANATE NO FURTHER EXPOSURE CAN BE PERMITTED.

First Aid

First Aid:SKIN:WASH AREA THORO W/SOAP & H*2O. REMOVE SOILED CLTHG &
WASH BEFORE REUSE. GET MD IF IRRIT PERSISTS. EYE:FLUSH W/LG AMTS OF
H*2O FOR @ LST 15 MIN. GET MD. INGEST:GET MD IMMED. DO NOT INDUCE
VOMIT. A SPIR OF MATL INTO LUNGS CAN CAUSE CHEM PNEUM WHICH MAY BE
FATAL. INHAL:IF BRTHG DFCLT, OBTAIN FRESH AIR. IF CONTINUED DFCLTY
IS EXPER, CALL MD IMMED. IF BRTHG STOPS, USE CPR & CALL MD IMMED.

Fire Fighting

Flash Point Method:TCC
Flash Point:24.0F,-4.4C
Lower Limits:1.1%
Extinguishing Media:DRY CHEMICAL OR FOAM.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT . USE CO*2. SUMMON PROFESSIONAL FIREFIGHTERS.
Unusual Fire/Explosion Hazard:KEEP AWAY FROM HEAT, SPKS & OPEN FLAME.
DO NOT SMOKE EXTING ALL SOURCES OF IGNIT, UNTIL ALL VAPS ARE GONE.
KEEP GOOD VENT TO PVNT VAP BUILD UP.

Accidental Release

Spill Release Procedures:ABSORB LIQUID W/INERT MATL SUCH AS PAPER, RAGS
OR SAND. SHOVEL INTO PROPER WASTE CONTAINERS. ELIMINATE ALL
IGNITION SOURCES, WEAR PROPER PROT EQUIP. VENTILATE AWAY ALL
VOLATILE FUMES.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP CNTNRS CLSD & UPRIGHT WHEN NOT IN
USE. DO NOT STORE >120F. DO NOT TRANSFER CONTENTS TO PLASTIC
BOTTLES/OTHER UNLABELED CNTNRS.
Other Precautions:CNTNRS OF THIS MATL MAY BE HAZ WHEN EMPTIED BECAUSE
THEY RETAIN PROD RESIDUES (VAPS, LIQS &/OR SOLIDS). PROD IS FOR
INDUS USE ONLY BY PROFESSIONAL, TRAINED PERS USING PROPER EQUIP.
NOT INTENDED FOR SA LE TO OR USE BY GENERAL PUBLIC.

Exposure Controls

Respiratory Protection:MAINTAIN CONTINUOUS FLOW OF UNCONTAMINATED FRESH
AIR TO A NIOSH/MSHA APPROVED POSITIVE PRESSURE HOOD OR MASK. DO NOT
BREATHE VAPORS, SPRAY MISTS OR SANDING DUSTS.
Ventilation:PROVIDE SUFFICIENT MECHANICAL VENTILATION TO MAINTAIN
EXPOSURE LIMITS BELOW TLV AT ALL TIMES.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEM WRKRS GOG & FULL LGTH FSHLD .
Other Protective Equipment:AT ALL TIMES, WEAR PROTECTIVE CLOTHING TO
PREVENT SKIN CONTACT.EMERG EYE WASH AND DELUGE SHOWER IN IMMED AREA
OF USE.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
MFR'S TRADE NAME/PART NO:G3010 92-C39. EFTS OF OVEREXP:NIOSH REC EGEEA
BE REGARDED IN WORKPLACE AS HAVING POTNTL TO CAUSE ADVERSE REPRO
EFTS IN WORKERS ALSO CAN CAUSE IRRIT TO MUC MEMBS, MILD A LLERGEN,
NARC EFTS, CORNEAL EFTS, INJURY TO KIDNEYS & LIVER, RESP SENSIT
RSLTS IN ASTHMA-LIKE SYMPTOMS ON (INGRED 6)

Chemical Properties

Boiling Pt:B.P. Text:>168F,>76C
Vapor Pres:SEE INGRED
Vapor Density:HVR/AIR
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:NOT RELEVANT
Percent Volatiles by Volume:64

Stability

Stability Indicator/Materials to Avoid:YES
OXIDIZING MATLS. AVOID CNTCT W/H*2O, ALCOHOLS, AMINES, STRONG BASES,
METAL CMPDS/SURF ACTIVE MATLS.
Stability Condition to Avoid:AVOID EXCESSIVE HEAT.
Hazardous Decomposition Products:WHEN HEATED TO DECOMP EMITS TOXIC
FUMES:CO, CO*2 & NO*X.

Disposal

Waste Disposal Methods:DISPOSE OF CONTAMINATED ABSORBENT WASTE & UNUSED
CONTENTS I/A/W LOCAL, STATE & FEDERAL REGULATIONS. DO NOT
INCINERATE. WHEN HEATED, MATERIAL DECOMPOSITION GIVES OFF TOXIC
FUMES.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.